Skip to main content
. 2007 Jul 30;5:83. doi: 10.1186/1477-7819-5-83

Table 5.

Variables influencing whether a residual ultrasound lesion is seen on interval follow-up ultrasound imaging for cases in which an attempt was originally made to completely excise the breast lesion and in which interval follow-up ultrasound imaging was obtained (n = 170)

All cases
(n = 170)
No residual ultrasound lesion seen
(n = 151)
Residual ultrasound lesion seen
(n = 19)
P-value
Was the original breast lesion palpable 0.242
 Yes 77
(45%)
66
(44%)
11
(58%)
 No 93
(55%)
85
(56%)
8
(42%)
Original ultrasound lesion measurements
 Dimension 1 (cm) 1.13
(0.37–3.12)
1.10
(0.37–2.48)
1.44
(0.90–3.12)
< 0.001
 Dimension 2 (cm) 0.98
(0.24–2.52)
0.93
(0.24–1.96)
1.32
(0.69–2.52)
< 0.001
 Dimension 3 (cm) 0.63
(0.22–1.50)
0.60
(0.22–1.50)
0.85
(0.53–1.17)
0.007
 Volume of lesion (cubic cm) 0.35
(0.01–4.36)
0.33
(0.01–3.48)
0.83
(0.23–4.36)
< 0.001