TABLE III.
Individual and mean thresholds (dB SPL) for experiment 3, predicted values of COMOD and COMOD MIRROR Sπ thresholds (dB SPL) based upon optimal combination of OSB binaural and across-frequency monaural masking cues, and the Difference (dB) between the predicted and obtained COMOD Sπ thresholds. Values in parentheses for mean data are inter-listener standard deviations.
Obtained | Predicted | ||||
---|---|---|---|---|---|
So | Sπ | Sπ | Difference | ||
L1 | COMOD | 53.5 | 49.1 | 51.2 | 2.1 |
MIRROR | 54.0 | 50.4 | 51.3 | 0.9 | |
L2 | COMOD | 55.1 | 49.8 | 53.6 | 3.8 |
MIRROR | 57.1 | 51.9 | 53.9 | 2.0 | |
L3 | COMOD | 58.8 | 52.5 | 56.4 | 3.9 |
MIRROR | 59.0 | 53.6 | 56.3 | 2.7 | |
L5 | COMOD | 54.8 | 50.4 | 54.0 | 3.6 |
MIRROR | 56.8 | 52.4 | 55.0 | 2.6 | |
L6 | COMOD | 56.0 | 51.5 | 54.4 | 2.9 |
MIRROR | 58.6 | 53.3 | 55.1 | 1.8 | |
X̄ | COMOD | 55.6 (2.0) | 50.7 (1.3) | 53.9 (1.9) | 3.2 (0.8) |
MIRROR | 57.1 (2.0) | 52.3 (1.2) | 54.3 (1.9) | 2.0 (0.7) |