Skip to main content
. Author manuscript; available in PMC: 2007 Oct 1.
Published in final edited form as: Med Phys. 2007 Jul;34(7):3109–3118. doi: 10.1118/1.2748106

Table I.

Mean and standard deviation of adipose tissue CT numbers in axial breast mastectomy specimen CBCT images.

Variation in mean value (CT #) Variation in standard deviation (CT #)
Min Max Min Max
Medium size specimen
Before correction −136 −116 16 31
After correction −36 −21 10 10.5
Large size specimen
Before correction −225 −190 60 72
After correction −35 −14 11 14