Table 2.

Definitions of Baseline Candidate Variables for the Pooled Analyses

OHTS EGPS
Age Age at baseline same
IOP Mean of right and left eyes using 4–6 IOP measurements per eye at the 2 Qualifying Visits and 2–3 IOP measurements per eye at the Randomization Visit Mean of right and left eyes using 2–3 IOP measurements at the Eligibility Visit and 1 IOP measurement at the 6 month visit
CCT Mean of right and left eyes of 5 measurements per eye taken at one visit using ultrasonic pachymeter Same
Vertical Cup/Disc Ratio by Contour Mean of right and left eye of estimates from stereophotographs by masked readers Same
Visual Field Pattern Standard Deviation Mean of right and left eyes of two normal and reliable baseline Humphrey
30-2 visual fields per eye done at qualifying visits
Mean of right and left eyes of two normal and reliable baseline Humphrey
30-2 visual fields or Octopus 32-2 visual fields per eye done at the qualifying visit
Octopus loss variance converted to pattern standard deviation
History of Diabetes Self-report at baseline Self-report at baseline of diabetes and its treatment
History of Heart Disease Self-report Self-report

CCT Central corneal thickness

EGPS European Glaucoma Prevention Study

IOP Intraocular pressure

OHTS Ocular Hypertension Treatment Study