Table 4.
Validation of the Basic and Covariate Models: Errors in predictions of AmB concentrations using the Validation Data Set (n = 226).
Parameter | Basic model | Covariate model1 |
---|---|---|
Prediction error (mg l–1) | 0.0057 | 0.0089 |
Mean (95% CI) | (−0.0093, 0.0208) | (−0.0075, 0.0252) |
Root square prediction error (mg l–1) | 0.1145 | 0.1245 |
Mean (95% CI) | (0.1034, 0.1587) | (0.1131, 0.1349) |
95% CI=lower and upper limits of the 95% confidence interval.
The data were modelled with clearance as a function of weight0.75 and method of administration and volume of distribution as a function of weight.