Skip to main content
. 2001 Nov;52(5):573–577. doi: 10.1046/j.0306-5251.2001.01490.x

Table 2.

Rates of major errors in different parts of the process of prescribing and giving acetylcysteinea.

Operation Rate of major error Approximate 95% confidence intervals
Calculation 3/57 (5%) 2.3–8.2%
Drawing up acetylcysteine and adding it to glucose 7/184 (3%) 1.0–6.6%
Mixing 12/128 (9%) 4.3–14.4%
Sampling 1/184 (0.5%) 0.0–1.6%
Analysis assumed zero
a

Major errors are assumed when values differ by more than 50% from anticipated values, or when the difference between two samples (pre and postinfusion) is more than 50%.