Table 1.

Magnitude of the heart motion (in mm) taking the CT at end-expiration (CTEXPIR) as reference. Mid-ventricular slice, averaged over all 22 subjects.

Mean Displacement (mm) Relatively to CTEXPIR CTMIDVOL CTINSPIR
Apex 11.6±2.3 18.1±6.2

Mid-ventricular SA
 Anterior 6.8±1.0 14.3±2.5
 Lateral 6.9±3.1 13.0±2.5
 Inferior 8.3±2.9 12.6±3.6