Table 1.
Parameter values used under standard conditions
| Parameters | Values |
| Cm | 300 fF (30) |
| RK | 71 MΩ (710) |
| RNa | 710 MΩ (7100) |
| EK | -94 mV |
| ENa | +60 mV |
| Rd | 5000 MΩ |
| Cd | 30 pF |
| Ror | 1.0 KΩ |
| Rol | 1.0 KΩ |
| Ri | 500 KΩ |
| Rjc | 25 MΩ |
Values for junctional units given in parentheses
Cm = Total cell capacitance
RK = Potassium resistance
RNa = Sodium resistance
EK = Potassium equilibrium potential
ENa = Sodium equilibrium potential
Rd = Resistance in delay circuit for second black-box to bring about AP repolarization
Cd = Capacitance in delay circuit for second black-box
Ror = Radial resistance of external fluid
Rol = Longitudinal resistance of external fluid
Ri = Longitudinal resistance of intracellular fluid
Rjc = Radial resistance of junctional cleft