Skip to main content
. 2006 Mar 21;63(7):482–487. doi: 10.1136/oem.2005.024638

Table 5 Change in lung function during a workshift before and after implementation of smoking ban (n = 69).

Parameter Before smoking ban After smoking ban, mean (SD) p Value comparing changes
Pre‐shift, mean (SD) Post‐shift, mean (SD) Change, mean (SD) Change (%) Pre‐shift, mean (SD) Post‐shift, mean (SD) Change, mean (SD) Change (%)
FVC 4.63 l (0.99) 4.55 l (1) −81 ml (136) −1.8 4.49 l (0.93) 4.44 l (0.95) −52 ml (156) −1.2 0.24
FEV1 3.73 l (0.80) 3.64 l (0.8) −89 ml (132) −2.4 3.52 l (0.71) 3.48 l (0.73) −46 ml (152) −1.4 0.09
FEF25–75% 3.74 l/s (1.35) 3.54 l/s (1.33) −199 ml/s (372) −5 3.33 l/s (1) 3.26 l/s (1) −64 ml/s (307) −1.7 0.01
PEF 564 l/min (147) 577 l/m (154) 14 l/min (87) 3.9 576 l/min (152) 584 l/min (150) 9 l/min (63) 2.5 0.11

*Cross shift changes significantly changed from before application of smoking ban p<0.05 (Student's paired t test).