Table 1 Definition of study variables.
Variable | Definition |
---|---|
Absolute stent recoil | (Balloon diameter by angiography) − (stent diameter by IVUS after stent placement) |
Achieved balloon‐to‐artery ratio | (Maximum stent balloon diameter by angiography in a single view) ÷ (mean prestent vessel diameter by IVUS) |
Cross‐sectional area stenosis at stent minimum LD | (1 − (Minimum in‐stent lumen area)/(stent area)) × 100 |
Immediate LD gain | (Minimum LD immediately after stent placement) − (minimum LD before stent placement) |
In‐stent volume stenosis | (1 − (stent lumen volume)/(in‐stent neointimal volume + stent lumen volume)) × 100 |
Late‐loss index | (Late lumen loss) ÷ (immediate lumen gain) |
Late lumen loss | (Minimum LD immediately after stent placement) − (minimum LD at day 28) |
Neointima beyond the stent edges | Total distance from proximal and distal stent edges that displayed neointimal thickness of ⩾0.25 mm by IVUS at day 28 |
Neointimal thickness | Average neointimal thickness based on four measurements made every 1 mm along the length of the stent |
Net lumen diameter change | (Minimum LD at day 28) − (prestent LD) |
Percentage cross‐sectional area stenosis | (1 −(average cross‐sectional area at stent minimum LD by IVUS at day 28) ÷ (average prestent vessel area by IVUS)) × 100 |
Percentage LD stenosis | (Average of major and minor axes at the lesion minimum LD by IVUS at day 28) ÷ (average prestent vessel diameter by IVUS) × 100 |
Prestent vessel diameter by IVUS | Average of major and minor axis measurements, from external elastic membrane to external elastic membrane in the mid‐portion of the region where stent placement was intended |
Relative stent recoil | (Absolute stent recoil) ÷ (balloon diameter by angiography) |
Stent symmetry index | (Minor axis stent minimum LD) ÷ (major axis stent minimum LD). Measured at the stent mid‐length |
IVUS, intravascular ultrasound; LD, lumen diameter.