Skip to main content
. 2007 Feb 2;11(1):R14. doi: 10.1186/cc5680

Table 2.

Cardiorespiratory parameters measured in the four groups of piglets before death

Cardiorespiratory parameters Group p value
Control NVI VNI VI
Number of animals 5 6 6 8

pH 7.41 ± 0.04 7.38 ± 0.04 7.40 ± 0.27 7.40 ± 0.10 0.12
PaO2/FiO2 (mm Hg) 414 ± 82 385 ± 38 279 ± 130a 208 ± 113b,c <0.001
PaCO2 (mm Hg) 37 ± 6 41 ± 3 40 ± 7 44 ± 7 0.16
Ppeak (cm H2O) 19 ± 1 NP 28 ± 14 37 ± 14 0.05
Pplat (cm H2O) 15 ± 3 NP 20 ± 11 27 ± 10 0.07
Crs (ml/cm H2O) 25 ± 7 NP 20 ± 6 16 ± 6a <0.05
MAP (mmHg) 116 ± 11 106 ± 11 92 ± 12a 74 ± 24b,c 0.001

ap < 0.05 versus control; bp < 0.01 versus control; cp < 0.05 versus NVI. Data are expressed as mean ± standard deviation. Crs, respiratory compliance; MAP, mean arterial pressure; NP, not performed; NVI, non-ventilated-inoculated piglets; PaCO2, arterial partial pressure of carbon dioxide; PaO2/FiO2, arterial partial pressure of oxygen/fraction of inspired oxygen; Ppeak, maximum peak airway pressure; Pplat, end-inspiratory plateau airway pressure; VI, ventilated-inoculated piglets; VNI, ventilated-non-inoculated piglets.