Skip to main content
. 2007 Oct 18;7:71. doi: 10.1186/1472-6750-7-71

Table 3.

Growth-related data for varying cell lines grown in spinner flasks

Cell Type Cell line Maximum growth rate during the exponential growth phase (hours-1) from 3 different runs Maximum viable cell density (106 cells/mL)
Run 1 Run 2 Run 3 Average Change vs. Control (%)

HeLa control 0.027 0.026 0.026 1.49 ± 0.03
+ cdkl3 0.031 0.032 0.032 20 1.53 ± 0.03
+ cox15 0.030 0.030 0.031 15 1.66 ± 0.02
HEK-293 control 0.030 0.030 0.032 1.98 ± 0.02
+ cdkl3 0.035 0.037 0.037 19 2.04 ± 0.04
+ cox15 0.034 0.036 0.034 13 2.15 ± 0.05
HEK-293 ACRP30 control 0.031 0.031 0.032 1.94 ± 0.04
+ cdkl3 0.037 0.037 0.035 16 2.01 ± 0.02
+ cox15 0.036 0.035 0.036 14 2.10 ± 0.06
CHO control 0.033 0.034 0.034 1.95 ± 0.01
+ cdkl3 0.036 0.037 0.037 9 2.04 ± 0.02
+ cox15 0.036 0.035 0.035 5 2.09 ± 0.03
MDCK control 0.029 0.030 0.030 1.12 ± 0.04
+ cdkl3 0.030 0.029 0.030 0 1.10 ± 0.02
+ cox15 0.028 0.029 0.028 -5 1.08 ± 0.07