Skip to main content
. Author manuscript; available in PMC: 2008 Dec 1.
Published in final edited form as: Int J Radiat Oncol Biol Phys. 2007 Oct 29;69(5):1634–1641. doi: 10.1016/j.ijrobp.2007.08.023

Table 2.

Tumor excursion from RCCT and RC-CBCTs for the study population. Tumor excursion was measured as the difference in centroid position between the end inhalation and end exhalation phase images. (LR = left to right direction, AP = anterior-posterior direction, CC = cranio-caudal direction, CBCT = cone beam CT, RCCT = planning respiration-correlated CT, RC-CBCT = respiration-correlated cone beam CT).

Tumor Excursion, RCCT Tumor Excursion Range, RC-CBCTs
Subject LR (cm) AP (cm) CC (cm) Number of CBCTs LR (cm) AP (cm) CC (cm)
1 0.15 0.20 0.39 3 0.10–0.20 0.10–0.20 0.20–0.30
2 0.08 0.30 0.61 3 0.15–0.18 0.30–0.52 0.80–0.98
3 0.31 0.45 0.99 3 0.07–0.14 0.41–0.50 0.61–0.83
4 0.37 0.22 0.80 1 0.55–0.55 0.38–0.38 0.72–0.72
5 0.16 0.18 0.88 7 0.08–0.32 0.10–0.30 1.07–1.37
6 0.34 0.72 1.84 7 0.15–0.44 0.14–0.88 0.94–1.89
7 0.37 1.44 1.15 5 0.14–0.57 0.71–1.35 1.01–1.30
8 0.34 0.45 1.88 4 0.07–0.66 0.40–0.58 1.20–1.83
Mean 0.27 0.50 1.07