Skip to main content
. 2007 Oct 18;35(21):7171–7187. doi: 10.1093/nar/gkm752

Table 4.

The percentage of ssDNA length covered by hRad51 and the initial velocity of polymerization under different experimental conditions

Buffer type [hRad51] varies Force is fixed (6pN) [hRad51] is fixed = 3 µM Forces varies


200 nM 3 µM 2.0 ± 0.2 pN 4.0 ± 0.4 pN 6.0 ± 0.6 pN
ATP, A buffer (2 mM Mg2+) 13 ± 5% 24 ± 5%
7.4 ± 0.2 nm s−1 44.2 ± 0.2 nm s−1
700±20 monomers min−1 4210 ± 20 monomers min−1
ATP, B buffer (5 mM Ca2+) 36 ± 5% 88 ± 5% 24 ± 5% 67 ± 5% 88 ± 5%
12.8 ± 0.2 nm s−1 80 ± 10 nm s−1 13 ± 1 nm s−1 80 ± 10 nm s−1 80 ± 10 nm s−1
1220 ± 20 monomers min−1 8000 ± 1000 monomers min−1 1100 ± 90 monomers min−1 7400 ± 900 monomers min−1 8000 ± 1000 monomers min−1

The error bars are given by the fit for each individual experiment. Each case of the table contains three lines: Line 1: percent coverage; Line 2: polymerization rate in nm/s; Line 3: Polymerization rate in monomers per min.