Skip to main content
. Author manuscript; available in PMC: 2008 Dec 1.
Published in final edited form as: J AAPOS. 2007 Oct 29;11(6):532–540. doi: 10.1016/j.jaapos.2007.09.005

Table 1.

ROP expert sensitivity, specificity, and receiver operating characteristic area under the curve (AUC) for detection of plus disease, compared to the reference standard of majority vote among 22 recognized ROP experts.

Expert # Sensitivity Specificity AUC (SE*)
1 0.462 1.000 0.859 (0.063)
2 0.615 1.000 0.982 (0.018)
3 0.615 1.000 0.890 (0.057)
4 1.000 0.667 0.833 (0.070)
5 0.308 1.000 0.951 (0.035)
6 0.846 0.714 0.784 (0.082)
7 0.846 0.952 0.921 (0.052)
8 0.923 0.905 0.921 (0.052)
9 0.923 0.905 0.921 (0.052)
10 0.778 1.000 0.918 (0.065)
11 0.538 0.857 0.885 (0.061)
12 0.769 1.000 0.956 (0.032)
13 0.692 1.000 0.934 (0.041)
14 1.000 1.000 1.000 (0.000)
15 0.750 0.952 0.899 (0.058)
16 0.923 0.810 0.879 (0.061)
17 0.846 1.000 0.967 (0.029)
18 1.000 0.750 0.875 (0.080)
19 0.923 0.857 0.896 (0.059)
20 1.000 0.952 0.976 (0.028)
21 1.000 0.571 0.786 (0.077)
22 1.000 0.952 0.976 (0.028)
*

SE, Standard error.