Skip to main content
. 2007 Apr 11;16(9):1325–1331. doi: 10.1007/s00586-007-0314-1

Table 3.

Intra-observer reproducibility of the constrained and non-constrained Cobb techniques for each observer based on intra-class correlation coefficients (95% confidence interval)

Measuring technique Thoracic kyphosis Lumbar lordosis
Observer 1 Observer 2 Observer 3 Observer 1 Observer 2 Observer 3
Non-constrained Cobb 0.74 (0.49–0.87) 0.90 (0.79–0.95) 0.92 (0.84–0.96) 0.97 (0.94–0.99) 0.97 (0.93–0.98) 0.90 (0.80–0.95)
Constrained Cobb 0.80 (0.60–0.90) 0.81 (0.65–0.91) 0.92 (0.83–0.96) 0.95 (0.90–0.98) 0.96 (0.91–0.98) 0.87 (0.72–0.94)