Skip to main content
. 2004 Dec;124(6):663–677. doi: 10.1085/jgp.200409178

TABLE II.

Conductance–Voltage Data for HCN2 Channels

Control Saturating cAMP
HCN2 channel Vhalf (mV) Slope (mV) Vhalf (mV) Slope (mV) ΔVhalf (mV)
Wild type (7) −125 ± 2.0 3.76 ± 0.30 −111 ± 1.7 4.18 ± 0.24 14.3 ± 1.8
K472E (4) −113 ± 3.1 9.59 ± 0.89 −112 ± 2.9 9.06 ± 0.91 0.75 ± 1.3
E502K (6) −128 ± 2.9 5.66 ± 0.97 −116 ± 2.8 5.4 ± 1.1 12.3 ± 0.94
K472E + E502K (4) −125 ± 3.8 5.55 ± 0.82 −110 ± 3.4 5.72 ± 0.41 14.9 ± 1.6
D542K (5) −124 ± 1.9 7.03 ± 0.61 −114 ± 1.9 6.35 ± 0.75 10.1 ± 1.4
K472E + D542K (3) −133 ± 1.9 3.65 ± 0.57 −119 ± 3.6 3.52 ± 0.31 14.2 ± 1.9
E502K + D542K (4) −118 ± 2.8 7.58 ± 1.4 −122 ± 2.8 7.27 ± 1.1 −3.9 ± 0.95

All values are mean ± SEM. The n values are in parentheses after each channel construct. ΔVhalf = Vhalf cAMP − Vhalf control.