Table.

Failure Stress (σf), Critical Flaw Size (c), Semi-minor (a) and Semi-major (2b) Axes of the Specimens, and Residual Stress (σR)

Sample ID a (μm) 2b (μm) c (μm) Failure Stress (MPa) Crack Initiation Site Material
1 376 1129 460 116 Connector (gingival surface) Experimental core ceramic
2 94 1223 240 161 Posterior abutment margin Experimental core ceramic
3 361 918 407 124 Connector (occlusal surface) Experimental core ceramic
4 282 941 364 131 Connector (occlusal surface) Experimental core ceramic
5 188 706 258 156 Connector (occlusal surface) Experimental core ceramic
6 283 1367 440 27+22 (σR) Connector (occlusal surface) Experimental core ceramic/glass veneer
7 376 1543 539 107 Connector (occlusal surface) Experimental core ceramic
8 229 829 308 32+22 (σR) Connector (occlusal surface) Experimental core ceramic/glass veneer
9 791 2232 939 19+22 (σR) Veneer chipping Experimental core ceramic/glass veneer
10 283 1367 440 68+22 (σR) Veneer chipping Experimental core ceramic/glass veneer