Skip to main content
. 2008 Feb 28;27(7):982–992. doi: 10.1038/emboj.2008.34

Table 1.

Summary of treadmilling factors (TMFs) and half-times of fluorescence recovery (t1/2) measured in this study

Component TMF t1/2
Actin 0.436 21.3
p16 0.327 9.2
Actinnarrow 0.282 11.1
Actintip 7.5
p16tip 7.1
Abi 13.6
WAVE 8.6
Cttn 0.155 6.4
Cttn II 0.159 3.8
CP 7.2
Cofilin 0.061 6.5
Cofilinactive 0.076 4.2
Cofilininactive 0.066 2.8
VASP 14.4
Actinnarrow (also termed n-actin in Figure 2) corresponds to values obtained from actin movies measured as done for p16 expressers. The average width of measured areas in p16 expressors was approximately 1 μm, whereas the tip measurements were done on regions with a dimension of approximately 0.5 μm. The average width analysed in lamellipodia of actin expressers was 2.8 μm.