Skip to main content
. 2008 Jan 31;3:6. doi: 10.1186/1748-717X-3-6

Table 4.

Heart dose and target coverage with and without conformal shielding of the heart

Heart Breast PTVCT
Mean dose (Gy) Volume ≥ 30 Gy (%) Volume receiving ≥ 95% of prescribed dose (%)

3D-CRT 3D-CRT with shielded heart 3D-CRT 3D-CRT with shielded heart 3D-CRT 3D-CRT with shielded heart

Patient
1 4.8 2.0 5.1 0.0 98.9 93.8
2 2.9 2.1 1.4 0.0 98.9 97.5
3 3.4 2.0 2.5 0.0 99.1 90.3

Dosimetric results with and without deliberate multileaf collimator shielding of the heart in the tangential breast beams. Results based on cumulative dose plans (breast plan 50 Gy + boost plan 16 Gy). Patients had upper-quadrant tumor sites. Boost PTVCT target coverage was not compromised.

3D-CRT: three-dimensional conformal radiation therapy; PTV: planning target volume; PTVCT: computed tomography (CT)-based PTV.