Test # Cast Material Layers of cast Cotton Stockin-ette Present? Cast Padding Type Layers of Cast pad H20 Dip Temp (°C) 1 m 5 m 10 m 15 m 20 m 25 m 30 m 35 m 40 m Peak
Repeated Tests for Plaster and Fiberglass
1 SFPR 12 Yes Webril 1 32 27 27.5 28.5 34 35 34 X X X 35
2 SFPR 12 Yes Webril 1 32 28 28 28.5 31 34 34 X X X 34.5
3 SFPR 12 Yes Webril 1 32 29 29 29 32 34 33.5 X X X 34
10 DLFR 7 Yes Webril 1 32 31.5 33 33.5 31 X X X X X 33.5
11 DLFR 7 Yes Webril 1 32 31.5 33 34.5 31.5 X X X X X 34.5
12 DLFR 7 Yes Webril 1 32 30 31.5 32 30 X X X X X 33.5
Effect of Layers of Cast Material on Temperature Underneath
4 SFPS 16 Yes Webril 1 32 27.5 29 28.5 29 32 33.5 X X X 33.5
5 SFPS 12 Yes Webril 1 32 29.5 29.5 29 29.5 31 33.5 X X X 33.5
6 SFPS 20 Yes Webril 1 32 30 30 30 30.5 32.5 33.5 X X X 35.5
7 SEFPR 12 Yes Webril 1 32 28 30 35 41 38 X X X X 41
8 SEFPR 16 Yes Webril 1 32 30 32.5 40.5 41 36.5 X X X X 41
9 SEFPR 20 Yes Webril 1 32 33 37 46.5 45 40 X X X X 46.5
14 DLFR 10 Yes Webril 1 32 32 33.5 36 32.5 X X X X X 36
15 DLFR 10 Yes Webril 1 32 32.5 35 38 36 X X X X X 38
16 DLFR 12 Yes Webril 1 32 31 33 39 38 X X X X X 39
Effect of Cast Padding Thickness and Types
21 DLFR 7 Yes Webril 3 32 31.5 34 34.5 33 X X X X X 34.5
22 DLFR 7 Yes Webril 5 32 31.5 34 33.5 32 X X X X X 34
23 3MSFR 7 No Procel 1 32 30 34.5 37 33 X X X X X 37
24 3MSFR 7 No Procel 3 32 28 30 34 32 X X X X X 34
25 SFPR 20 Yes Webril 1 39 29.5 30 32.5 37.5 38 35 X X X 38
26 SFPR 20 Yes Webril 3 39 31.5 32 35.5 42.5 44 41 X X X 44
27 SFPR 20 Yes Webril 5 39 33 33 36 42.5 44 41 X X X 44
Pillow Effect
28 SFPR 20 Yes Webril 1 39 32 32.5 36.5 46.5 53 54 53 50.5 48 54
29 SFPR 12 Yes Webril 1 32 29 29 31.5 32.5 43 45.5 45.5 X X 45.5
Effect of Dip Water, Temp, Splints, etc.
13 3MSFR 7 Yes Webril 1 32 32 36 36.5 32 X X X X X 36.5
17 DLFR 7 Yes Webril 1 39 34 36.5 36.5 33 X X X X X 36.5
18 3MSFR 7 Yes Webril 1 39 35 39.5 37.5 33 X X X X X 39.5
19 3MSFR 7 No Prepadded 1 39 34 32 31.5 30 X X X X X 34
20 3MSFR 7 No Prepadded 1 32 27 30 35 33 X X X X X 35
30 SFPR 20 Yes Webril 1 39 33 34 39 43 42 39 X X X 43
31 SFPR 12 Yes Webril 1 39 29 30 31 34 36 35.5 X X X 36

Presents the data from all tests performed. The purpose of the test is described in the text and grouped by numbers (i.e., tests 1–3 and 10–12 are reproducibility of measures tests for plaster and fiberglass respectively. Data organized in columns represents controlled and variable factors including: plaster type, material thickness, padding thickness, dip water temperature, dip water purity, ambient humidity and temperature, as well as the outcomes measure of temperature over time.