Skip to main content
. 2002 Mar 1;539(Pt 2):623–636. doi: 10.1113/jphysiol.2001.013291

Table 3.

Basic electrophysiological measures for the three modelled cells together with the optimal parameter values and ranges

Cell 1 Cell 2 Cell 3
Temperature (°C) 26 36 25 37 26 35
Basic measures
  Em (mV) −65 −65 −64 −68 −69 −71
  τ0 (ms) 28.2 13.0 43.1 25.3 32.9 16.4
  Q/a0 (pC/mV) 0.25 0.29 0.20 0.24 0.24 0.26
  RN (MΩ) 125.8 55.2 240.8 128.5 156.5 79.3

Derived models
  Cm (μF cm−2) 0.94 0.94 0.79 0.78 0.96 0.85
(0.77−1.12) (0.73–1.31) (0.77–1.01) (0.74–0.99) (0.85–1.26) (0.68–1.22)
  Ri (Ω cm)
  Long fits 155 140 265 160 200 170
(73−305) (29–375) (180–325) (66–265) (155–245) (61–240)
  Short fits 110 110 250 40 200 170
(94–230) (38–310) (190–285) (18–215) (180–225) (140–210)
  Gtot(nS) 8.3 18.4 3.8 7.2 6.0 11.2
(7.8–9.4) (17.7–24.1) (3.8–4.7) (7.0–9.2) (5.5–7.9) (10.1–15.8)
  Gsh (nS) 1.8 7.3 3.8 7.0 3.5 7.7
(0–4.7) (0–11.3) (3.4–4.0) (6.0–7.8) (2.7–4.2) (6.9–9.0)
  Rm (kΩ cm2) 37.4 21.9 14 200 998 90.2 61.9
(27–94) (11–42) (330–450 000) (150–400 000) (59–150) (40–105)

Average dendritic electrotonic length (length constants, γ)
  Apical 0.76 0.95 0.061 0.18 0.83 0.93
  Basal 0.29 0.36 0.023 0.068 0.26 0.29

The optimal values are shown with the range of acceptable values in parentheses underneath. For Ri, a second range of parameters is given for fits done over 2–15 ms.