Skip to main content
. 2002 Mar 15;539(Pt 3):693–705. doi: 10.1113/jphysiol.2001.013129

Table 3.

Comparison of observed third moment of the mean (μ3observed) with the ideal third moment (μ3ideal) calculated from the measured p values for asynchronous release in Sr2+ solutions

p μ3observed μ3ideal μ3observed3ideal
0.0529 0.04515 0.0448 1.0078
0.0583 0.0484 0.0485 0.9979
0.0495 0.0429 0.0424 1.0117
0.0443 0.0384 0.0385 0.9964
0.032 0.0285 0.0288 0.9896
0.071 0.0568 0.0563 1.0089
0.066 0.0542 0.0535 1.0131
0.0449 ± 0.0447 ±
0.004 0.004

The values in the bottom row are means ± 1 s.e.m.