Table 3.
Comparison of observed third moment of the mean (μ3observed) with the ideal third moment (μ3ideal) calculated from the measured p values for asynchronous release in Sr2+ solutions
p | μ3observed | μ3ideal | μ3observed/μ3ideal |
---|---|---|---|
0.0529 | 0.04515 | 0.0448 | 1.0078 |
0.0583 | 0.0484 | 0.0485 | 0.9979 |
0.0495 | 0.0429 | 0.0424 | 1.0117 |
0.0443 | 0.0384 | 0.0385 | 0.9964 |
0.032 | 0.0285 | 0.0288 | 0.9896 |
0.071 | 0.0568 | 0.0563 | 1.0089 |
0.066 | 0.0542 | 0.0535 | 1.0131 |
— | 0.0449 ± | 0.0447 ± | — |
0.004 | 0.004 |
The values in the bottom row are means ± 1 s.e.m.