Skip to main content
. 2002 Apr 15;540(Pt 2):543–556. doi: 10.1113/jphysiol.2001.013121

Table 1.

Electrophysiological membrane properties of DAP(+) and DAP(−) vagotomized NGNs

Vagotomized NGNs

Parameter Control NGNs (n = 36) DAP(+) (n = 46) DAP(−) (n = 36)
Em (mV) −46 ± 1 −51 ± 1* −52 ± 1*
Cm (pF) 37 ± 2 46 ± 2* 40 ± 2
Rin (MΩ) 389 ± 34 412 ± 30 300 ± 26
AP overshoot (mV) 51 ± 2 46 ± 2 50 ± 2
AP peak hyperpolarization (mV) −70 ± 0 −66 ± 3* −68 ± 0*
AP duration (ms) 1.6 ± 0.2 1.4 ± 0.1 1.5 ± 0.1
Rheobase (pA) 108 ± 23 193 ± 18* 289 ± 26*
1 × threshold (#APs) 2 ± 1 2 ± 1* 1 ± 0*
2 × threshold (#APs) 6 ± 1 3 ± 1* 2 ± 0*
3 × threshold (#APs) 7 ± 1 3 ± 2* 3 ± 0*
0.1–0.9 nA (#APs) 15 ± 3 4 ± 2* 3 ± 1*

Em (mV), membrane potential; Rin (MΩ), membrane input resistance; Cm (pF), membrane capacitance; AP overshoot (mV), most positive membrane potential during a single evoked AP; AP peak hyperpolarization (mV), most negative membrane potential during at single evoked AP; AP duration (ms), AP width at 0 mV; rheobase, minimum 750 ms current required to induce an AP; 1 × threshold (#APs), number of APs evoked by a 750 ms 1 × threshold depolarizing current; 2 × threshold (#APs), number of APs evoked by a 750 ms 2 × threshold depolarizing current; 3 × threshold (#APs), number of APs evoked by a 750 ms 3 × threshold depolarizing current; 0.1–0.9 nA (#APs), maximum number of APs evoked by a single 750 ms of magnitude 100–900 pA. Values are means ±s.e.m.

*

Significantly different from control.

Denotes significantly different from DAP(−) vagotomized NGNs.