Table 2.
Name | Created by | Content |
---|---|---|
File1.pfl | Created by a user; modified by “Adjust parameters” and “Automatic count” modules | A list of detection parameters is followed by a list of the files analyzed |
Data1.txt | “Automatic count” module | Each line represents a single EPSC or mEPSC and includes: number of detected quantal events; onset; termination; amplitude; integrated signal; latencies of all the quantal peaks |
Data.av | “Automatic count” module | Each of the six columns represents: an average failure of transmission; an average EPSC classified as unitary; an average EPSC classified as double quantal; an average EPSC classified as triple quantal; an average mEPSP; an average sweep |
File.res | “Quantal Content” module | All the calculated parameters of synaptic activity (Table 3) |
File.mqc | “Quantal Content” module | Distribution of countal content obtained by direct counts |
File.qaa | “Quantal Content” module | Distribution of quantal sizes |
File.tam | “Quantal Content” module | Distribution of EPSC sizes |
File.lat | “Quantal Content” module | Latency distribution |
The filename “File” is selected by user
2 The filename “Data” corresponds to the name created by acquisition software (PClamp, Axon Instruments)