Table 2b.

Weighted means (WM 12–24 h) for active treatment comparisons

Tio vs. S100 Tio vs. S50 S100 vs. S50
FEV1 0.01 (−0.05, 0.06) 0.12 (0.06, 0.17)* 0.11 (0.06, 0.17)*
MMEF −0.02 (−0.07, 0.03) 0.05 (−0.001, 0.09) 0.07 (0.02, 0.11)*
sGaw 1.12 (1.02, 1.23)* 1.23 (1.12, 1.34)* 1.10 (1.00, 1.20)*
RV −0.04 (−0.20, 0.12) −0.17 (−0.33, −0.02)* −0.13 (−0.29, 0.02)
R5 −0.06 (−0.09, −0.02)* −0.09 (−0.12, −0.05)* −0.03 (−0.06, 0.01)
R15 −0.03 (−0.05, −0.01)* −0.04 (−0.07, −0.02)* −0.01 (−0.04, 0.01)
R20 −0.02 (−0.03, 0.001) −0.02 (−0.04, −0.01)* −0.01 (−0.03, 0.01)
R25 −0.02 (−0.03, 0.002) −0.03 (−0.05, −0.02)* −0.02 (−0.03, 0.00)
R35 −0.01 (−0.02, 0.01) −0.02 (−0.03, −0.002)* −0.01 (−0.02, 0.01)
RF −2.30 (−3.83, −0.77)* −3.64 (−5.16, −2.11)* −1.33 (−2.86, 0.19)
X5 0.03 (−0.01, 0.06) 0.06 (0.02, 0.09)* 0.03 (−0.003, 0.06)

Tio, Tiotropium bromide 18 µg; S100, salmeterol 100 µg; S50, salmeterol 50 µg. Data are

mean difference (95% confidence intervals) or

geometric mean (95% confidence intervals).

*

Superiority of Tio over S100, Tio over S50 or S100 over S50. Data for static lung volumes are not shown as no significant differences seen. FEV1, Forced expiratory volume in 1 s; MMEF, maximum mid-expiratory flow; sGaw, specific airway conductance; RV, residual volume; R, resistance; X, reactance.