TABLE 1.
Properties of different fluorescent probes upon binding to fibrillar AS
2,6-ANS | 2,6-TNS | bis-ANS | bis-TNS | ThioT | |
---|---|---|---|---|---|
![]() |
471 | 475 | NA | NA | NA |
![]() |
417 | 437 | 493 | 505 | 483 |
![]() |
1.22 ± 0.01 | 0.35 ± 0.01 | 0 | 0 | 0 |
![]() |
167 ± 2 | 169 ± 2 | 198 ± 3 | 124 ± 2 | 21 ± 1† |
![]() |
0.61 | 0.64 | 1 | 0.66 | — |
![]() |
8.8 ± 0.5 | 11.7 ± 0.4 | 8.6 ± 0.5 | 11.6 ± 0.7 | 14.9 ± 0.4† |
![]() |
0.29 | 0.30 | 0.34 | 0.33 | 0.38 |
![]() |
4.2/0.10 | 3.9/0.10 | 3.4/0.22 | 3.3/0.27 | 0.5/0.23 |
9.9/0.90 | 10.3/0.90 | 7.3/0.88 | 7.0/0.73 | 2.1/0.77 |
NA, not applicable.
and
are the maximum wavelengths of fluorescence emission spectrum of the unbound and bound dye, respectively.
Values in the range 20–90 and 1–15 μM were obtained for and
respectively, for different fibril preparations.
Standard deviation errors of fitted lifetimes were typically 0.1 ns for the fast component and 0.05 ns for the slow component.