Table 1.
Ion | Nuclear Reaction | Photopeak (keV) | Irradiation Timea | Irradiation Timeb | Decay Time | Count Time | Count Position |
---|---|---|---|---|---|---|---|
F | F19(n,γ)F20 | 1633 | 7 sec | 15 sec | 15 sec | 30 sec | Face |
P | P31(n,α)Al28 | 1779 | 15 sec | 15 sec | 1 min | 3 min | Face |
Na | Na23(n,γ)Na24 | 1368 | 7 sec | 15 sec | 1 min | 10 min | 1 spind |
Mg | Mg26(n,γ)Mg27 | 844, 1014 | 7 sec | 15 sec | 1 min | 10 min | 1 spin |
Ca | Ca48(n,γ)Ca49 | 3085 | 7 sec | 15 sec | 1 min | 10 min | 1 spin |
K | K41(n, γ)K42 | 1524 | 95 sec | 360 sec | EOIc | 30 min | 1e |
Zn | Zn68(n, γ)Zn69m | 438 | 95 sec | 360 sec | EOIc | 30 min | 1e |
Irradiation time for tibiae from two and four month old animals.
Irradiation time for tibiae from one month old animals.
EOI: End of Irradiation Time is the specific time the sample exited the reactor. All samples and standards were decay corrected back to this time.
Count position was in a rotating position 2.5 cm from the detector face.
Count position was in a stationary position 2.5 cm from the detector face.