Skip to main content
. Author manuscript; available in PMC: 2008 Jun 20.
Published in final edited form as: J Acoust Soc Am. 2008 Mar;123(3):1522–1543. doi: 10.1121/1.2836786

TABLE II.

Spatial tuning curve parameters in Clarion subjects.

Slopes (dB/mm)
Subject probe rEL Ave Lp (%DRμA) Apical Basal Bandwidth (mm) Tip shift (mm) Ap/Am (dB)
C23rEL07:M 34 −0.41 0.40 9.00 −2.11 0.0
15 −0.25 0.41 9.09 −1.54 0.7
C05rEL08:M 31 −0.32 0.57 7.18 0.27 0.1
21 −0.30 0.38 7.48 −0.34 −1.1
17 −0.21 0.74 6.70 0.19 −1.4
8 −0.21 0.69 9.64 −1.86 −0.5
C18rEL07:M 20 −1.76 0.65 3.51 1.97 3.0
8 −1.70 0.14 5.03 2.44 1.2
C03rEL08:M 21 −1.04 1.20 1.67 −0.05 −0.3
17 −1.05 1.26 1.96 −0.13 −0.1
14 −0.27 1.31 6.05 −0.57 0.3
C16rEL07:M 24 −2.29 2.58 0.83 −0.02 −2.1
13 −2.19 1.58 1.16 0.13 −0.6
11 −2.03 2.83 2.25 0.63 0.4
D08rEL08:MP 29 −2.15 3.05 2.70 0.00 −2.2
21 −2.15 1.77 2.22 0.02 −0.8
17 −2.44 2.09 2.37 −0.06 −0.8
Ave (C) 18.9 −1.22 1.27 4.64 −0.06 −0.2
Sdev (C) 7.5 0.89 0.92 3.05 1.15 1.2
Min (C) 7.6 −0.21 0.14 0.83 −2.11 −2.2
Max (C) 33.5 −2.44 3.05 9.64 2.44 3.0