Skip to main content
. 2008 Apr 18;74(12):3774–3782. doi: 10.1128/AEM.02049-07

TABLE 3.

Light fluences, survival ratios, and normalized E1A and DNA concentrations obtained for control (C) and disinfected samples (S1 and S2) for the inactivation of adenovirus serotype 2 with UV lighta

Expt/sample IT (mJ/cm2) N/N0 (n) Normalized E1A density (n) Normalized DNA concn (n) P
UV-M-1/C 0.0 1.000 (1) NAb 1.000 (1)
UV-M-1/S1 12.8 0.431 (1) NA 0.069 (1)
UV-M-1/S2 29.8 0.100 (1) NA 0.034 (1)
UV-M-2/C 0.0 1.000 (1) 1.000 (2) 1.000 (2)
UV-M-2/S1 12.8 0.588 (1) 0.760 ± 0.047 (2) 0.084 ± 0.024 (2)
UV-M-2/S2 29.8 0.140 (1) 0.360 ± 0.244 (2) 0.095 ± 0.030 (2)
UV-M-3/C 0.0 1.000 (1) 1.000 (1) 1.000 (8)
UV-M-3/S1 8.8 0.619 (1) 0.312 (1) 0.119 ± 0.032 (8)
UV-M-3/S2 23.4 0.424 (1) 0.054 (1) 0.018 ± 0.020 (8)
UV-M-1 to UV-M-3/C 0.0 1.000 (3) 1.000 (2) 1.000 (3)
UV-M-1 to UV-M-3/S1 11.5 ± 1.3 0.546 ± 0.058 (3) 0.536 ± 0.224 (2) 0.091 ± 0.015 (3) 0.0289
UV-M-1 to UV-M-3/S2 27.7 ± 2.1 0.221 ± 0.102 (3) 0.207 ± 0.153 (2) 0.049 ± 0.023 (3) 0.386
a

Values given are averages for each separate experiment ± standard deviations (UV-M-1, UV-M-2, or UV-M-3) as well as sample composite averages for two (UV-M-2 and UV-M-3 for E1A samples) or all three (UV-M-1, UV-M-2, and UV-M-3 for DNA samples) experiments ± standard errors of the means.

b

NA, not available.