Table 7.
Exposure limits | Electric field Intensity E (V/m) | Magnetic field intensity H (A/m) | Power density D (W/m2) |
0,1 < f ≤ 3 MHz | 60 | 0,2 | - |
3 < f ≤ 3000 MHz | 20 | 0,05 | 1 |
3 < f ≤ 300 GHz | 40 | 0,01 | 4 |
Attention level | |||
0,1 MHz< f ≤ 300 GHz | 6 | 0,016 | 0,10 (3 MHz-300 GHz) |
Quality targets | |||
0,1 MHz< f ≤ 300 GHz | 6 | 0,016 | 0,10 (3 MHz-300 GHz) |