Skip to main content
. 2008 Jun 11;52(5):317–336. doi: 10.1093/annhyg/men029

Table 5.

Summary of respirable non-fibrous SiC levels by plant and job group, exposure intensity in samples collected with 6–8 h sampling time

Job group Respirable non-fibrous SiC (mg m−3)
Plant A Plant B Plant C
Unadjusted Adjusteda Unadjusted Adjusteda Unadjusted Adjusteda
Nb Kc AM GM GSDd GM P95e Nb Kc AM GM GSDd GM P95e Nb Kc AM GM GSDd GM P95e
Furnace
    Mix 13 3 0.014 0.009 2.6 0.010 0.72 9 4 0.066 0.036 3.0 0.034 0.22
    Charger 9 5 0.075 0.067 1.7 0.068 0.16
    Charger/mix 10 5 0.18 0.14 2.1 0.13 0.53
    Payloader 7 2 0.17 0.047 6.9 0.033 0.071 5 1 0.046 0.044 1.4 0.044 0.052 17 9 0.046 0.032 2.4 0.032 0.17
    Crane 23 7 0.014 0.008 2.6 0.008 0.097 17 5 0.019 0.015 2.2 0.015 0.052 13 5 0.016 0.004 3.2 0.004 0.16
    Control room 19 6 0.044 0.038 1.8 0.035 0.097 19 5 0.034 0.022 2.5 0.022 0.16 19 7 0.011 0.008 2.1 0.008 0.029
    Cleaning 2 1 0.54 0.49 1.9 0.49 0.77
    Sorting 20 5 0.10 0.086 1.7 0.083 0.26 18 4 0.48 0.24 3.1 0.22 3.6 18 9 0.35 0.31 1.7 0.31 0.68
Processing
    Refinery
        Crusher 29 11 0.89 0.65 2.4 0.65 2.1 13 3 0.54 0.36 2.5 0.39 2.1 19 6 0.69 0.45 2.4 0.46 3.8
        Other 27 11 0.11 0.087 2.0 0.087 0.30 26 14 0.26 0.11 3.6 0.11 1.2 31 8 0.38 0.22 2.8 0.27 1.4
    Fines 20 14 0.12 0.083 2.3 0.081 0.41 56 22 0.29 0.16 3.1 0.18 0.98 48 15 0.29 0.22 2.0 0.22 0.84
Maintenance
    Mechanics 47 17 0.098 0.054 3.0 0.053 0.40 48 18 0.14 0.076 3.1 0.079 0.52 28 9 0.075 0.039 2.8 0.042 0.28
    Electrician 20 7 0.068 0.052 2.2 0.052 0.17 20 7 0.12 0.068 2.5 0.067 0.55 10 5 0.086 0.038 3.9 0.038 0.33

There is no Norwegian OEL for respirable SiC; however, American Conference of Industrial Hygienists have suggested a threshold limit value of 3 mg m−3 (ACGIH, 2007).

a

Adjusted with mixed effect models.

b

Number of measurements.

c

Number of persons.

d

Geometric standard deviation.

e

95th percentile.