Skip to main content
. 2008 Jun 11;52(5):317–336. doi: 10.1093/annhyg/men029

Table 7.

Summary of total dust full-shift levels by plant and job group

Job group Total dust (mg m−3)
Plant A Plant B Plant C
Unadjusted Adjusteda Unadjusted Adjusteda Unadjusted Adjusteda
Nb Kc AM GM GSDd GM P95e Nb Kc AM GM GSDd GM P95e Nb Kc AM GM GSDd GM P95e
Furnace
    Mix 13 3 1.5 1.0 3.7 1.1 3.3 9 4 3.9 3.0 2.1 2.8 10
    Charger 8 5 4.6 4.1 1.7 4.2 7.4
    Charger/mix 10 5 9.3 7.6 1.8 7.3 24
    Payloader 7 2 2.7 1.3 3.6 1.1 10 5 1 1.2 1.1 1.8 1.0 1.9 18 9 2.0 1.3 2.6 1.3 6.7
    Crane 23 7 0.85 0.37 2.7 0.37 2.5 17 5 1.5 1.1 2.2 1.1 5.2 13 5 0.72 0.29 3.5 0.29 5.6
    Control room 19 6 1.3 1.2 1.7 1.1 2.8 20 5 1.3 1.1 2.0 1.0 3.0 19 7 1.3 1.1 2.0 1.1 3.5
    Cleaning 2 1 22 21 1.3 21 25
Sorting 20 5 1.1 0.82 2.1 0.82 3.9 20 4 5.0 2.9 3.2 2.7 17 18 9 5.3 4.8 1.6 4.5 11
Processing
    Refinery
        Crusher 28 11 7.4 4.8 2.5 4.8 30 12 3 4.0 3.2 2.0 3.5 9.8 19 6 4.7 3.4 2.2 3.5 23
        Other 25 11 1.4 1.1 1.9 1.1 3.5 27 14 2.5 1.2 3.1 1.1 9.3 31 8 2.7 2.1 2.1 2.4 6.3
    Fines 32 17 9.2 3.0 4.3 2.9 47 57 23 3.7 1.7 4.3 1.9 11 49 15 3.3 2.2 2.2 2.2 7.4
Maintenance
    Mechanics 48 17 1.5 1.0 2.5 1.0 4.7 47 18 3.1 2.0 2.8 2.0 7.9 28 9 1.8 1.3 2.3 1.4 6.7
    Electrician 20 7 1.3 0.95 2.3 0.97 3.2 23 7 2.0 1.1 3.1 1.1 7.7 10 5 1.8 0.88 3.0 0.88 9.3

The Norwegian OEL for total dust is 10 mg m−3 (The Norwegian Labour Inspection Authority, 2007).

a

Adjusted with mixed effect models.

b

Number of measurements.

c

Number of persons.

d

Geometric standard deviation.

e

95th percentile.