Skip to main content
. Author manuscript; available in PMC: 2008 Jul 31.
Published in final edited form as: Brain. 2007 Oct 10;131(Pt 1):50–59. doi: 10.1093/brain/awm241

Table 2.

Data from speech recordings made under different feedback conditions during scanning.

Measure PWS (N=12) CON (N=10)
Stuttered syllables (%)
  Normal 7.37 (1.94) 1.91 (0.37)
  Delayed 9.99 (2.98) 2.56 (1.51)
  Frequency-shifted 5.45 (1.90) 1.00 (0.25)
Sentence duration (s)
  Normal 3.12 (0.22) 2.58 (0.05)
  Delayed 3.57 (0.27) 3.08 (0.07)
  Frequency-shifted 3.19 (0.18) 2.85 (0.05)