Skip to main content
. 2008 Jun 17;23(9):863–868. doi: 10.1007/s00384-008-0487-z

Table 4.

Sensitivity and negative predictive value of imaging of the anastomosis (CT, contrast radiography or both modalities) depending on timing postoperatively and level of the anastomosis

  N Sensitivity % (CI) Negative predictive value % (CI)
Timing of imaging
7<days postop 43 53 (29–75) 92 (72–99)
7≥days postop 48 75 (53–89) 75 (53–89)
Level of anastomoses
distala 65 69 (51–83) 83 (65–94)
proximalb 26 50 (17–83) 83 (58–96)

CI = 95% confidence interval

aSigmoidresection, low anterior resection and subtotal or total colectomy