Subject Fp39, HiFocus™-II + EPS, 22 μs/phase, 1447 pps | |||||
Electrode | Insertion | Electric stimuli (C.U.) | Acoustic stimuli | ||
Length (mm) | Angle (°) | Frequency (Hz) | Level (dB SPL) | ||
1 | 16.7 | 517 | 381 (22) | 260 | 78.5 (2.8) |
2 | 15.8 | 495 | Broken wire | ||
3 | 14.9 | 454 | 384 (23) | 320 | 81 (2.7) |
4 | 14.0 | 413 | 390 (21) | 350 | 82 (4.2) |
5 | 13.1 | 370 | 412 (15) | 400 | 84 (0.3) |
6 | 12.2 | 338 | 414 (38) | 520 | 85.5 (0.4) |
7 to 16 | No contralateral hearing |