Fraction number | Absorbance of MNB at 412 nm (A.U.) | Ellipticity from circular dichroism (mdeg.cm−1) |
---|---|---|
1 | 0.01 | not seen |
2 | 0.31 | 0.67 |
3 | 0.05 | not seen |
4 | 0.05 | not seen |
5 | not seen | not seen |
6 | not seen | not seen |
7 | not seen | not seen |
8 | not seen | not seen |
9 | not seen | not seen |
10 | not seen | 5.43 |
11 | not seen | not seen |
The column volume was made of 1 mL of MNB-TPS beads. The column was loaded with 200 μl of 54.2 μM HS-EP36-HS DNA and washed with 10 ml 0.5 M sodium phosphate, pH=7.2, (fractions 1–9) and then eluted with 100 mM DTT in the same buffer. Fractions were 1 ml. Absorbance at 412 nm was measured using a Tecan plate reader and circular dichroism (ellipticity) was also measured. The data for all fractions for both measurements is shown but some are close to baseline in the scans and are reported as ‘not seen’.