Skip to main content
. 2008 Jul 18;95(8):3724–3737. doi: 10.1529/biophysj.108.137349

TABLE 1.

Electrical constants used in discrete multidomain and bidomain computational models

Electrical constants of fiber model
Parameter Value Reference
Myocyte conductivity 4 mS/cm (26,27)
Junctional resistance 1.125 Ωcm2 (26,28)
Membrane capacitance 1 μF/cm2 (29,30,26)
Extracellular conductivity 20 mS/cm (30,31)
Extracellular volume fraction 0.25 and 0.10 (3,32)