Skip to main content
. Author manuscript; available in PMC: 2009 Aug 7.
Published in final edited form as: J Biomech. 2008 Jul 9;41(11):2581–2584. doi: 10.1016/j.jbiomech.2008.05.023

Table 2.

Bland-Altman test values for precision measurements. All measured differences were less than the measured accuracy of the systems.

Output Bland-Altman
Mean S.D. 95 % confidence Mean−2S.D. Mean+2S.D.
Day 1 vs Day 2
EM_LD −0.009 0.065 −0.053 0.034 −0.139 0.121
EM CP −0.158 0.192 −0.287 −0.029 −0.542 0.226
EMCT LD 0.008 0.071 −0.040 0.055 −0.135 0.150
EMCT CP −0.133 0.170 −0.247 −0.018 −0.473 0.208
EM ROT −0.031 0.018 −0.060 −0.002 −0.068 0.005
OE LD 0.003 0.026 −0.015 0.02 −0.049 0.054
OE CP 0.003 0.037 −0.022 0.028 −0.072 0.078
OECT LD −0.032 0.102 −0.100 0.037 −0.236 0.172
OECT CP −0.008 0.101 −0.076 0.059 −0.210 0.193
OE ROT −0.039 0.063 −0.139 0.061 −0.164 0.087
System vs System+CT
EM LD 0.001 0.023 −0.009 0.011 −0.046 0.048
EM CP −0.088 0.067 −0.117 −0.058 −0.222 0.047
OE LD −0.011 0.078 −0.045 0.024 −0.167 0.145
OE CP −0.234 0.134 −0.294 −0.175 −0.503 0.034
EM vs OE
LD 0.024 0.059 −0.002 0.050 −0.095 0.143
CP 0.274 0.232 0.171 0.377 −0.190 0.738
CT LD 0.012 0.102 −0.033 0.057 −0.192 0.216
CT CP 0.127 0.188 0.044 0.211 −0.249 0.504
Rotation −0.066 0.057 −0.114 −0.018 −0.181 0.048