Photo-DSC results and degree of conversion (DC; mean ± standard deviation) calculated from photo-DSC (DCDSC) and FTIR (DCFTIR; a - mid FTIR data, b - NIR data) measurements (24 h post-cure).

Material group
Polymerization kinetics (photo-DCS data) DCDSC (%)
DCFTIR (%)
Time to Rmax (s)
Rmax (W/g)
E homopolymer
82.8
3.2
72.6 ± 2.2
97.0 ± 0.9a
H homopolymer
56.4
7.6
73.5 ± 2.2
97.0 ± 0.9a
BE copolymer
6.0
12.9
59.9 ± 1.8
89.9 ± 0.8a
BH copolymer
6.0
15.9
63.4 ± 1.9
86.2 ± 0.8a
BTE copolymer
-
-
-
85.5 ± 0.2b
BTH copolymer
-
-
-
85.4 ± 1.7b
BTE ACP composite
-
-
-
79.3 ± 0.8b
BTH ACP composite - - - 82.6 ± 1.7b
a

- mid FTIR data

b

- NIR data