Skip to main content
. 2008 Sep 30;64(Pt 10):911–913. doi: 10.1107/S1744309108026869

Table 1. X-ray diffraction data of the FERM–MT1-MMP complex.

Values in parentheses are for the outer resolution shell.

Beamline BL38B1, SPring-8
Detector Jupiter 315 detector
Wavelength (Å) 1.00
Temperature (K) 100
Oscillation range (°) 180 (180 × 1° images)
Exposure time (s) 15
Space group P6122
Unit-cell parameters (Å, °) a = b = 122.7, c = 128.3, γ = 120
Resolution (Å) 20–2.4 (2.47–2.40)
Reflections (total/unique) 48021/22917
Completeness (%) 100.0 (100.0)
Mosaicity 0.3–0.5
Multiplicity 21.0 (19.6)
I/σ(I)〉 15.6 (9.0)
Rmerge (%) 4.5 (27.5)

R merge = Inline graphic Inline graphic, where Ii(hkl) is the ith observed intensity of reflection hkl and 〈I(hkl)〉 is the average intensity over symmetry-equivalent measurements.