Skip to main content
. 2008 Jul 9;29(20):2514–2525. doi: 10.1093/eurheartj/ehn328

Table 3.

Multiple logistic regression analysis of dilated cardiomyopathy patients clinical characteristics and genotype to implantable cardioverter-defibrillator (history of ventricular tachycardia or ventricular fibrillation) prior to study entry (χ2 = 25.098; df = 10; P = 0.005)

Variable ICD (history of VT or VF)
OR 95% CI P-value
Genetic variant
 Ser96Ala (T→G)
  T/G compared with T/T 6.166 0.714–53.228 0.098
  G/G compared with T/T 18.213 1.974168.073 0.010

Clinical characteristics
 Age 1.061 1.0141.110 0.010
 Sex 1.504 0.422–5.359 0.529
 Familial DCM 0.394 0.133–1.166 0.093
 NYHA
  Class I compare with III 1.946 0.335–11.299 0.458
  Class II compare with III 1.530 0.298–7.863 0.610
 AF 0.630 0.164–2.421 0.501
 LBBB 0.439 0.136–1.415 0.168
 LVEF 0.963 0.890–1.041 0.338

ICD, implantable cardioverter-defibrillator; NYHA, New York Heart Association; AF, atrial fibrillation; LBBB, left bundle branch block; LVEF, left ventricular ejection fraction; OR, odds ratio; CI, confidence interval; df, degrees of freedom; with bold statistical significant associations.