Skip to main content
. 2008 Aug 22;74(20):6470–6472. doi: 10.1128/AEM.00552-08

TABLE 1.

Endotoxin measurements by the LAL testa

Solution Filtration time (h) Amt (EU/ml) of endotoxins in (charged) filter A sample:
Amt (EU/ml) of endotoxins in (charged) filter B sample:
Amt (EU/ml) of endotoxins in (noncharged) filter C sample:
Amt (EU/ml) of endotoxins in (noncharged) filter D sample:
1 2 1 2 1 2 1 2
CS 0 1 1 1 1 1 1 1 1
8 1 0.5 1 1 1 1 1 1
24 1 0.5 1 1 0.5 1 1 1
48 2 1 1 1 1 1 1 1
72 1 1 1 0.5 1 1 1 1
96 1 1 1 1 0.5 1 1 1
FF 0 <0.03 <0.03 <0.03 <0.03 <0.03 <0.03 0.125 0.03
8 <0.03 <0.03 <0.03 <0.03 0.5 1 0.25 0.5
24 <0.03 <0.03 <0.03 <0.03 1 0.5 1 1
48 <0.03 <0.03 <0.03 <0.03 2 8 1 1
72 0.03 <0.03 <0.03 <0.03 0.5 0.5 2 1
96 <0.03 <0.03 <0.03 <0.03 0.5 2 1 1
Conclusionb R R R R NR NR NR NR
a

Results for 2 samples representative of the 20 samples analyzed per filter are shown. Filters A and C were obtained from GVS, and filters B and D were obtained from Pall.

b

R, the filter retained endotoxins; NR, the filter did not retain endotoxins.