Skip to main content
. 2008 Aug 14;105(4):1114–1126. doi: 10.1152/japplphysiol.00177.2008

Table 3.

Estimated values of the kinetic parameters descriptive of rotenone-dicumarol-insensitive CoQ1 reduction and CoQ1H2 oxidation on passage through normoxic lungs, a measure of the relative precision of estimates of these parameters, and correlation coefficients between these parameters

Parameters Estimated Values CV, % Correlation Matrix
Vmax3, μmol/min 0.86 20.1 1 0.76 −0.06 0.16
Km3a, μM 65.6 77.4 1 −0.08 0.56
Vmax4, μmol/min 4.6 3.2 1 0.60
Km4a, μM 75.9 14.5 1

Vmax3 and Km3a are the respective maximum rate and apparent Michaelis-Menten constant for coenzyme Q1 (CoQ1) reduction via rotenone-dicumarol-insensitive reductase(s); Vmax4 and Km4a are the respective maximum rate and apparent Michaelis-Menten constant for CoQ1 hydroquinone (CoQ1H2) oxidation via complex III. Parameter values were estimated from the mean values of the normoxic data in Figs. 3 and 4C. The values of Vmax3, Km3a, Vmax4, and Km3a for hyperoxic lungs are assumed to be the same as those estimated for normoxic lungs. CV, asymptotic coefficient of variation.