Skip to main content
. 2006 Oct;23(10):764–768. doi: 10.1136/emj.2006.036269

Table 2 Primary analysis, comparing the results of the index test with the reference standard in all patients with a complete per‐protocol dataset.

Index test Delayed troponin Total
Positive Negative
Positive 41 203 244
Negative 1 32 33