Table 1. Theoretical time (ms) to reach detection threshold.

Stimulus condition

Stimulus intensity Luminance S-cone increment S-cone decrement
2 × threshold 137 247 303
4 × threshold 93.3 180 227
8 × threshold 73.3 143 183
12 × threshold 63.3 127 163

Stimulus temporal profile was assumed to be 190 ms sinusoidal increment, 190 ms constant in the maximum modulation and 190 ms sinusoidal decrement, as in McKeefry et al. (2003). Impulse response functions in Fig. 4 were used and the temporal step size in this calculation was 3.33 ms. Zero time is defined as the stimulus onset (no delay, reaction latency or time for motor response is included).