Skip to main content
. 2008 Nov 7;1:110. doi: 10.1186/1756-0500-1-110

Figure 4.

Figure 4

Extrapolation of strain-specific insertions. The number of specific insertions is plotted as a function of the number n of strains. For each n, markers are the 6!/[(n - 1)!·(6 - n)!] values obtained for the different strain combinations. The continuous curve represents the least-squares fit of the function Fs(n) = κs exp [-ns] + Ω where κs = 578.35 ± 198.07, -1/τs = -1.36 ± 0.18 and Ω = 5.1 ± 1.1. The best fit was obtained with a correlation of 0.998.