Skip to main content
. Author manuscript; available in PMC: 2008 Dec 8.
Published in final edited form as: Med Image Comput Comput Assist Interv. 2008;11(Pt 1):376–383. doi: 10.1007/978-3-540-85988-8_45

Table 1.

Error analysis with respect to manual ground truth

Image Cells Method Avg. Area (pixels) Avg. Error (%) RMS
1 9 Regular GAC 1872 -51.9% 2038
Proposed 3947 1.4% 243
2 6 Regular GAC 2259 -21.1% 838
Proposed 3137 7.2% 213
3 12 Regular GAC 2797 -14.9% 692
Proposed 3327 0.4% 130
4 9 Regular GAC 2367 -28.7% 1216
Proposed 3476 2.5% 262
####
Total 36 Regular GAC 2368 -28.6% 1298
Proposed 3488 2.3% 212