Table 1.
Tensile testing samples and electrospinning parameters. (Note: DCM: dichloromethane, MtOH: methanol, H2O: water. a: humidity level = 31%–43%. b: humidity level = 68%–72%. The temperature during electrospinning ranged from 20 to 25 °C.)
Sample name | Solvent (volume ratio) | Concentration (wt ratio) | Electrospinning parameters | Tensile test sample size, n |
---|---|---|---|---|
PCLEEP64 6%, a | DCM:MtOH (6:4) | 6 wt% | 0.3 ml h−1; 6 kV; a | 15 |
PCLEEP64 6%, b | DCM:MtOH (6:4) | 6 wt% | 0.3 ml h−1; 6 kV; b | 12 |
H2O120 | DCM:MtOH (6:4) | 6 wt% | 0.5 ml h−1; 7 kV; a | 18 |
H2O:DCM/MtOH (1:20) | ||||
H2O140 | DCM:MtOH (6:4) | 6 wt% | 0.4 ml h−1; 6 kV; a | 15 |
H2O:DCM/MtOH (1:40) | ||||
H2O150 | DCM:MtOH (6:4) | 6 wt% | 0.4 ml h−1; 7 kV; a | 17 |
H2O:DCM/MtOH (1:50) | ||||
PCLEEP64 8% | DCM:MtOH (6:4) | 8 wt% | 0.8 ml h−1; 7 kV; a | 16 |
PCLEEP 12% | DCM | 12 wt% | 8 ml h−1; 6 kV; a | 19 |
RA0.03 | DCM:MtOH (6:4) | 6 wt% PCLEEP | 0.2 ml h−1; 6.5 kV; b | 20 |
PCLEEP:RA (99.97:0.03) | ||||
RA0.3 | DCM:MtOH (6:4) | 6 wt% PCLEEP | 0.5 ml h−1; 6.5 kV; b | 22 |
PCLEEP:RA (99.7:0.3) | ||||
RA1 | DCM:MtOH (6:4) | 6 wt% PCLEEP | 0.5 ml h−1; 7 kV; a | 18 |
H2O:DCM/MtOH (1:40) | PCLEEP:RA (99:1) | |||
RA10 | DCM:MtOH (6:4) | 6 wt% PCLEEP | 0.5 ml h−1; 7 kV; a | 15 |
H2O:DCM/MtOH (1:40) | PCLEEP:RA (90:10) | |||
RA20 | DCM:MtOH (6:4) | 6 wt% PCLEEP | 0.5 ml h−1; 6 kV; a | 20 |
H2O:DCM/MtOH (1:40) | PCLEEP:RA (80:20) | |||
BSA10 | DCM | 8 wt% PCLEEP | 0.9 ml h−1; 8 kV; a | 19 |
PCLEEP:BSA (90:10) | ||||
BSA20 | DCM | 8 wt% PCLEEP | 0.8 ml h−1; 8 kV; a | 17 |
PCLEEP:BSA (80:20) | ||||
PCL64 8% | DCM:MtOH (6:4) | 8 wt% | 0.8 ml h−1; 8 kV; a | 21 |
PCL64 10% | DCM:MtOH (6:4) | 10 wt% | 1.0 ml h−1; 9 kV; a | 17 |
PCL64 12% | DCM:MtOH (6:4) | 12 wt% | 1.2 ml h−1; 6kV; a | 17 |