Skip to main content
. Author manuscript; available in PMC: 2008 Dec 10.
Published in final edited form as: IEEE Trans Plasma Sci IEEE Nucl Plasma Sci Soc. 2007 Jun;35(3):559–564. doi: 10.1109/TPS.2007.896931

TABLE I.

Operational Parameters and Resulting Output Power of the 140-GHz Gyrotron for the DNP/NMR Experiments

140 GHz
Operation voltage, Vo (kV) 12
Beam current, Io (mA) 25
Operating mode TE031
Tube output mode TE01
Magnetic field, Bo (T) 5.1
Cyclotron harmonic number 1
Output power (W) 14