TABLE I.
Operational Parameters and Resulting Output Power of the 140-GHz Gyrotron for the DNP/NMR Experiments
| 140 GHz | |
|---|---|
| Operation voltage, Vo (kV) | 12 |
| Beam current, Io (mA) | 25 |
| Operating mode | TE031 |
| Tube output mode | TE01 |
| Magnetic field, Bo (T) | 5.1 |
| Cyclotron harmonic number | 1 |
| Output power (W) | 14 |